Transformerless Power supply requirements and capacitor selection:
Below is the table for output current and output voltage (without the Load), of different values of X-rated capacitors:
Capacitor Code
|
Capacitor value
|
Voltage
|
Current
|
104k
|
0.1 uF
|
4 v
|
8 mA
|
334k
|
0.33 uF
|
10 v
|
22 mA
|
474k
|
0.47 uF
|
12 v
|
25 mA
|
684k
|
0.68 uF
|
18 v
|
100 mA
|
105k
|
1 uF
|
24 v
|
40 mA
|
225k
|
2.2 uF
|
24 v
|
100 mA
|
Selection of voltage dropping capacitor is important, it is based on Reactance of Capacitor and the amount of current to be withdrawn. The Reactance of the capacitor is given by below formula:
X = 1 / 2¶fC
X = Reactance of Capacitor
f = frequency of AC
C = Capacitance of X rated capacitor
We have used 474k means 0.47uF capacitor and frequency of AV mains is 50 Hz so the Reactance X is:
X = 1 / 2*3.14*50*0.47*10-6 = 6776 ohm (approx)
Now we can calculate the current (I) in the circuit:
I = V/X = 230/6775 = 34mA
So that’s how the Reactance and Current is calculated.